1.
Arq. bras. oftalmol ; 87(5): e2022, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1527847

ABSTRACT

ABSTRACT Purpose: To explore the therapeutic effects of orthokeratology lens combined with 0.01% atropine eye drops on juvenile myopia. Methods: A total of 340 patients with juvenile myopia (340 eyes) treated from 2018 to December 2020 were divided into the control group (170 cases with 170 eyes, orthokeratology lens) and observation group (170 cases with 170 eyes, orthokeratology lens combined with 0.01% atropine eye drops). The best-corrected distance visual acuity, best-corrected near visual acuity, diopter, axial length, amplitude of accommodation, bright pupil diameter, dark pupil diameter, tear-film lipid layer thickness, and tear break-up time were measured before treatment and after 1 year of treatment. The incidence of adverse reactions was observed. Results: Compared with the values before treatment, the spherical equivalent degree was significantly improved by 0.22 (0.06, 0.55) D and 0.40 (0.15, 0.72) D in the observation and control groups after the treatment, respectively (p<0.01). After the treatment, the axial length was significantly increased by (0.15 ± 0.12) mm and (0.24 ± 0.11) mm in the observation and control groups, respectively, (p<0.01). After the treatment, the amplitude of accommodation significantly declined in the observation group and was lower than that in the control group, whereas both bright and dark pupil diameters significantly increase and were larger than those in the control group (p<0.01). After the treatment, the tear-film lipid layer thickness and tear break-up time significantly declined in the two groups (p<0.01). Conclusions: Orthokeratology lens combined with 0.01% atropine eye drops can synergistically enhance the control effect on juvenile myopia with high safety.


RESUMO Objetivo: Explorar os efeitos terapêuticos das lentes de ortoceratologia combinados com colírio atropina 0,01% em miopia juvenil. Métodos: Um total de 340 pacientes com miopia juvenil (340 olhos) tratados entre 2018 e Dezembro de 2020 foram divididos em Grupo Controle (170 casos com 170 olhos, lentes de ortoceratologia) e Grupo Observação (170 casos com 170 olhos, lentes de ortoceratologia combinadas com colírio atropina 0,01%). A acuidade visual melhor corrigida para longe, acuidade visual melhor corrigida para perto, dioptria, comprimento axial, amplitude de acomodação, diâmetro da pupila brilhante, diâmetro da pupila escura, espessura da camada lipídica da película lacrimal e tempo de ruptura do rasgo foram medidos antes do tratamento e 1 ano depois. A incidência de reações adversas foi observada. Resultados: Antes do tratamento, o grau esférico equivalente foi significativamente melhorado em 0,22 (0,06, 0,55) D e 0,40 (0,15, 0,72) D respectivamente no Grupo Observação e no Grupo Controle após o tratamento (p<0,01). Após tratamento, o comprimento axial foi significativamente aumentado em (0,15 ± 0,12) mm e (0,24 ± 0,11) mm respectivamente nos Grupos Observação e controle (p<0,01), enquanto, no grupo de observação, a amplitude de acomodação diminuiu significativamente e foi inferior a do Grupo Controle, e o diâmetro da pupila brilhante e o diâmetro da pupila escura aumentaram significativamente e foram maiores do que os do Grupo Controle (p<0,01). A espessura da camada lipídica da película lacrimal e o tempo de ruptura do rasgo diminuíram significativamente nos dois grupos (p<0,01) após o tratamento. Conclusões: As lentes de ortoceratologia combinadas com colírio atropina 0,01% podem melhorar significativamente o efeito controle em miopia juvenil com elevada segurança.

2.
Arq. bras. oftalmol ; 86(6): e2021, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520196

ABSTRACT

ABSTRACT Purpose: The purpose of this study was to compare the white-to-white distance measurements of two devices (IOL Master 500 and Atlas corneal topographer) commonly used in clinical practice to determine if they were interchangeable. Providing information on instrument interchangeability could eliminate several unnecessary tests and consequently reduce the economic burden for the patient and society. Methods: In this prospective, comparative case series, the white-to-white distance was measured by independent examiners using the Atlas topographer (Carl Zeiss Meditec) and the IOL Master 500 (Carl Zeiss Meditec). One eye each of 184 patients was tested. Statistical analyses were performed using a paired t-test, Pearson correlation analysis, and Bland-Altman analysis to compare the measurement methods. Results: The mean white-to-white distance measurements with the Atlas topographer and the IOL Master 500 were 12.20 ± 0.44 mm and 12.12 ± 0.41 mm, respectively (p<0.001). The mean white-to-white difference between the two devices was 0.07 mm (95% confidence interval of mean difference: 0.04-0.11 mm). The Pearson correlation coefficient between the two devices was 0.85 (p<0.0001). The 95% limits of agreement between the two devices were -0.38 mm to 0.53 mm. Conclusions: The Atlas topographer and IOL Master 500 can be used interchangeably with respect to white-to-white distance measurements, as the range of differences is unlikely to affect clinical practice and decision making.


RESUMO Objetivo: O objetivo deste estudo é comparar as medições de diâmetro corneano de dois dispositivos normalmente utilizados na prática clínica (IOL Master 500 e Atlas topógrafo corneal) para ver se são permutáveis. O fornecimento de informações sobre a permutabilidade de instrumentos poderia eliminar vários testes desnecessários e, consequentemente, reduzir a carga econômica para o paciente e para a sociedade. Métodos: Nesta série de casos prospectivos e comparativos, a distância do diâmetro corneano foi medida por examinadores independentes utilizando o Topógrafo Atlas (Carl Zeiss Meditec) e o IOL Master 500 (Carl Zeiss Meditec), em um olho de 184 pacientes. A análise estatística foi realizada utilizando o teste t pareado, a correlação Pearson e a análise Bland-Altman para comparar os métodos de medição. Resultados: As medições médias da distância do diâmetro corneano com o topógrafo Atlas e o IOL Master 500 foram de 12,20 ± 0,44 mm e 12,12 ± 0,41 mm, respectivamente (p<0,001). A diferença média de WTW entre os dois dispositivos foi de 0,07 mm (intervalo de confiança de 95% da diferença média: 0,04 - 0,11 mm). O coeficiente de correlação Pearson entre os dois dispositivos foi de 0,85, p<0,0001. Os limites de concordância de 95% entre os dois dispositivos foram de -0,38 mm a 0,53 mm. Conclusões: O Atlas topographer e o IOL Master 500 podem ser utilizados permutavelmente em relação à medição do diâmetro corneano, uma vez que a gama de diferenças encontradas é pouco susceptível de afetar a prática clínica e a tomada de decisões.

3.
Arq. bras. oftalmol ; 86(6): e2021, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1520202

ABSTRACT

ABSTRACT Purpose: To determine whether the axial length is associated with the education level in elderly patients with cataracts who were not exposed to electronic devices in the first two decades of life. Methods: This cross-sectional study was conducted in elderly patients with cataracts in Campinas, Brazil. Patients were divided into 2 groups: Group 1 included those who completed, at most, elementary school (including the illiterate and those who partially or totally attended elementary school), which corresponded to 12 years of schooling; Group 2 included, at least, high school graduates (including those who completed high school and those who partially or fully attended university). The sample was selected randomly with stratification for sex and age. The main outcome was the axial length. Results: The sample consisted of 472 elderly patients (236 per group) who underwent cataract surgery. There were 272 (57.6%) men and 200 (42.4%) women; the distribution was symmetrical between the two groups. The median age (IQR; range) was 66 (12; 50-89) years. The median axial length (IQR; range) was 22.82 (1.51; 20.34-28.71) mm in Group 1 and 23.32 (1.45; 20.51-31.34) mm in Group 2 (p<0.001). Conclusion: A greater axial length was associated with a higher level of education in elderly patients with cataracts, suggesting that myopization is related to an increase in activities requiring near-vision even before exposure to electronic devices.


RESUMO Objetivo: Determinar se o diâmetro axial está asso­ciado ao nível educacional em pacientes idosos com catarata que não foram expostos a dispositivos eletrônicos nas duas primeiras décadas de vida. Métodos: Este estudo transversal foi conduzido em pacientes idosos com catarata na cidade de Campinas, Brasil. Os Pacientes foram divididos em 2 grupos: no Grupo 1 foram incluídos aqueles que completaram, pelo menos, o ensino fundamental (incluindo analfabetos e aqueles com ensino fundamental completo ou incompleto), o que corresponde a 12 anos de escolaridade; no Grupo 2 foram incluídos indivíduos que, pelo menos, estudaram até o ensino médio (incluindo indivíduos com ensino médio completo e superior completo ou superior incompleto). A amostra foi selecionada aleatoriamente com estratificação por sexo e idade. O desfecho principal foi a medida do diâmetro axial. Resultados: A amostra foi constituída por 472 indivíduos que foram submetidos a cirurgia de catarata. Duzentos e trinta e seis indivíduos (50%) foram alocados no Grupo 1 e duzentos e trinta e seis indivíduos (50%) no Grupo 2. A mediana da idade (IIQ; intervalo) foi 66 (12; 50-89) anos. Duzentos e setenta e dois (57,6%) eram homens e duzentos (42,4%) mulheres, com distribuição simétrica entre os dois grupos. A mediana do diâmetro axial (IIQ; intervalo) foi 22,82 (1,51; 20,34-28,71) mm no Grupo 1 e 23,32 (1,45; 20,51-31,34) mm no Grupo 2 (p<0,001). Conclusão: Maiores medidas de diâmetro axial foram asso­ciadas a níveis educacionais mais elevados em pacientes idosos submetidos a cirurgia de catarata. Tal achado sugere que a miopização relacionada ao aumento de atividades que utilizam a visão de perto é fenômeno que ocorre antes mesmo da exposição a dispositivos eletrônicos.

4.
Arq. bras. oftalmol ; 85(3): 249-254, May-June 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1383808

ABSTRACT

ABSTRACT Purpose: Creating models, in pediatric cataracts, to estimate kerotometry and axial length values at future ages, based on kerotometry and axial length measured at surgery, to estimate the intraocular lens power for emmetropia in future ages. Methods: Eyes with bilateral cataract and kerotometry and axial length measured at surgery and at least one postoperative examination with kerotometry and axial length measurements, were considered for this study. The models to estimate future kerotometry and axial length values were created considering (1) kerotometry and axial length measured at surgery, (2) the average slope of kerotometry and axial length logarithmic regression created for every single eye and (3) age at surgery. The intraocular lens for future ages can be estimated using these values in third generation formulas. The estimation errors for kerotometry, axial length and intraocular lens were also calculated. Results: A total of 57 eyes from 29 patients met the inclusion criteria. The average age at the surgery and follow-up was 36.96 ± 32.04 months and 2.39 ± 1.46 years, respectively. The average slope of logarithmic regression created for every single eye were -3.286 for kerotometry and +3.189 for axial length. The average absolute estimation errors for kerotometry and axial length were respectively: 0.61 ± 0.54 D and 0.49 ± 0.55 mm, and for intraocular lens using SRK-T, Hoffer-Q and Holladay I formulas were: 2 . 04 ± 1 . 73 D , 2 . 49 ± 2 . 10 D and 2 . 26 ± 1 . 87 D, respectively. Conclusions: The presented models could be used to estimate the intraocular lens power for emmetropia at future ages to guide the choice of the intraocular lens power to be implanted in pediatric cataract.


RESUMO Objetivo: Criar modelos, em catarata pediátrica, para estimar valores futuros de ceratometria e comprimento axial, com base na ceratometria e no comprimento axial medidos na cirurgia, para previsão do poder da lente intraocular para emetropia em idades futuras. Métodos: Olhos com catarata bilateral, ceratometria e comprimento axial medidos na cirurgia e pelo menos um exame pós-operatório com medidas de ceratometria e comprimento axial foram considerados para este estudo. Os modelos para estimar futuras ceratometrias e comprimentos axiais foram criados considerando (1) ceratometria e comprimento axial medidos na cirurgia, (2) a inclinação média da regressão logarítmica da ceratometria e comprimento axial criada para cada olho e (3) a idade na cirurgia. A lente intraocular para emetropia em idades futuras pode ser estimada usando esses valores em fórmulas de terceira geração. Os erros de estimativa da ceratometria, comprimento axial e poder da lente intraocular, usando os modelos, também foram calculados. Resultados: 57 olhos de 29 pacientes preencheram os critérios de inclusão. A idade média na cirurgia e acompanhamento foram de 36,96 ± 32,04 meses e 2,39 ± 1,46 anos, respectivamente. A inclinação média da regressão logarítmica criada para cada olho foi de -3.286 para ceratometria e + 3.189 para o comprimento axial. Os erros médios de estimativa absoluta para ceratometria e comprimento axial foram respectivamente: 0,61 ± 0,54 D e 0,49 ± 0,55 mm, e para o poder da lente intraocular usando as fórmulas SRK-T, Hoffer-Q e Holladay I foram: 2,04 ± 1,73 D, 2,49 ± 2,10 D e 2,26 ± 1,87 D, respectivamente. Conclusões: Os modelos apresentados podem ser utilizados para estimar o poder da lente intraocular que levaria a emetropia em idades futuras e orientar a escolha do poder da lente intraocular a ser implantada na catarata pediátrica.

5.
Arq. bras. oftalmol ; 84(2): 107-112, Mar,-Apr. 2021. tab
Article in English | LILACS | ID: biblio-1153113

ABSTRACT

ABSTRACT Purpose: To investigate the effects of pharmacological accommodation and cycloplegia on ocular measurements. Methods: Thirty-three healthy subjects [mean (±SD) age, 32.97 (±5.21) years] volunteered to participate in the study. Measurement of the axial length, macular and choroidal thickness, refractive error, and corneal topography, as well as anterior segment imaging, were performed. After these procedures, pharmacological accommodation was induced by applying pilocarpine eye drops (pilocarpine hydrochloride 2%), and the measurements were repeated. The measurements were repeated again after full cycloplegia was induced using cyclopentolate eye drops (cyclopentolate hydrochloride 1%). The correlations between the measurements were evaluated. Results: A significant increase in subfoveal choroidal thickness after applying 2% pilocarpine was identified (without the drops, 319.36 ± 90.08 µm; with pilocarpine instillation, 341.60 ± 99.19 µm; with cyclopentolate instillation, 318.36 ± 103.0 µm; p<0.001). A significant increase in the axial length was also detected (without the drops, 23.26 ± 0.83 mm; with pilocarpine instillation, 23.29 ± 0.84 mm; with cyclopentolate instillation, 23.27 ± 0.84 mm; p=0.003). Comparing pharmacological accommodation and cycloplegia revealed a significant difference in central macular thickness (with pilocarpine instillation, 262.27 ± 19.34 µm; with cyclopentolate instillation, 265.93 ± 17.91 µm; p=0.016). Pilocarpine-related miosis (p<0.001) and myopic shift (p<0.001) were more severe in blue eyes vs. brown eyes. Conclusion: Pharmacological accommodation may change ocular measurements, such as choroidal thickness and axial length. This condition should be considered when performing ocular measurements, such as intraocular lens power calculations.(AU)


RESUMO Objetivo: Investigar os efeitos da acomodação farmacológica e da cicloplegia nas medições oculares. Métodos: participaram do estudo 33 voluntários saudáveis (média de idade [± DP], 32,97 anos [± 5,21 anos]). Foram medidos o comprimento axial, a espessura macular e coroidal e o erro refrativo, bem como realizados exames de imagem da topografia corneana e do segmento anterior. Em seguida, foi induzida a acomodação farmacológica aplicando-se colírio de pilocarpina (cloridrato de pilocarpina a 2%) e as medições foram repetidas nos participantes. As mesmas medições foram repetidas depois de induzir a cicloplegia completa com colírio de ciclopentolato (cloridrato de ciclopentolato a 1%) e foram avaliadas as correlações entre as medidas. Resultados: Identificou-se aumento significativo da espessura coroidal subfoveal com o uso da pilocarpina a 2% (sem colírio, 319,36 ± 90,08 µm; com a instilação de pilocarpina, 341,60 ± 99,19 µm; com a instilação de ciclopentolato, 318,36 ± 103,0 µm; p<0,001). Detectou-se também aumento significativo do comprimento axial (sem colírio, 23,26 ± 0,83 mm; com a instilação de pilocarpina, 23,29 ± 0,84 mm; com a instilação de ciclopentolato, 23,27 ± 0,84 mm; p=0,003). Ao se comparar a acomodação farmacológica e a cicloplegia, houve diferença significativa na espessura macular central (com a instilação de pilocarpina, 262,27 ± 19,34 µm; com a instilação de ciclopentolato, 265,93 ± 17,91 µm; p=0,016). Observou-se que a miose associada à pilocarpina (p<0,001) e o desvio miópico (p<0,001) foram mais severos nos olhos azuis que nos castanhos. Conclusão: A acomodação farmacológica pode alterar medidas oculares como a espessura da coroide e o comprimento axial. Essa possibilidade deve ser levada em consideração ao se efetuarem medições oculares, tais como cálculos de potência de lentes intraoculares.(AU)


Subject(s)
Humans , Choroid/anatomy & histology , Accommodation, Ocular , Pilocarpine/pharmacology , Corneal Topography/instrumentation , Axial Length, Eye/anatomy & histology , Mydriatics/pharmacology
6.
Rev. bras. oftalmol ; 79(5): 289-293, set.-out. 2020. tab
Article in Portuguese | LILACS | ID: biblio-1137987

ABSTRACT

Resumo Objetivo: Observar o grau de concordância das variáveis analisadas entre os dispositivos IOL Master 500 e Pentacam AXL e descrever as medias Métodos: Foram analisados 35 prontuários, totalizando 61 olhos. Todos os pacientes se submeteram à avaliação biométrica nos dois dispositivos, no período de agosto de 2018 a agosto de 2019. Os dados coletados foram: idade, sexo, profundidade da câmara anterior, comprimento axial, K1, K2, poder dióptrico da LIO e alvo refracional. Resultados: As médias das variáveis analisadas entre os dispositivos de biométricos óptica em questão tiveram diferença estatisticamente significante (p<0,05). A regressão linear não apontou influência de nenhuma das variáveis da câmara anterior na diferença de valores do poder dióptrico da LIO e do alvo refracional entre os dispositivos. Conclusão: Não houve concordância estatística entre os dispositivos para as variáveis analisadas. Portanto, deve se evitar intercambiar o uso do Pentacam AXL com o IOL Master 500.


Abstract Objective: Observe the agreement between IOL Master 500 and Pentacam AXL and describe the averages. Methods: We analyzed 35 medical records, totaling 61 eyes. All patients underwent biometric evaluation on both devices from August 2018 to August 2019. The data collected were: age, gender, anterior chamber depth, axial length, K1, K2, biometrics and IOL target. Results: The averages of the variables analyzed between the optical biometric devices in question had a statistically significant difference (p <0.05). Linear regression showed no influence of any anterior chamber variables on the difference in biometrics and target values between the devices. Conclusion: There was no statistical agreement between the devices for the analyzed variables. Therefore, the interchange of Pentacam AXL with IOL Master 500 should be avoided.


Subject(s)
Humans , Male , Middle Aged , Aged , Refraction, Ocular , Biometry , Axial Length, Eye , Multifocal Intraocular Lenses , Interferometry
7.
Arq. bras. oftalmol ; 83(4): 269-276, July-Aug. 2020. tab, graf
Article in English | LILACS | ID: biblio-1131618

ABSTRACT

ABSTRACT Purpose: To evaluate the influence of ocular axial length on circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in healthy eyes after correcting for ocular magnification effect. Methods: In this cross-sectional study, we evaluated 120 eyes from 60 volunteer participants (myopes, emmetropes, and hyperopes). The thickness of the circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer were measured using the spectral optical coherence tomography (OCT)-Cirrus HD-OCT and correlated with ocular axial length. Adjustment for ocular magnification was performed by applying Littmann's formula. Results: Before the adjustment for ocular magnification, age-adjusted mixed models analysis demonstrated a significant negative correlation between axial length and average circumpapillary retinal nerve fiber layer thickness (r=-0.43, p<0.001), inferior circumpapillary retinal nerve fiber layer thickness (r=-0.46, p<0.001), superior circumpapillary retinal nerve fiber layer thickness (r=-0.31, p<0.05), nasal circumpapillary retinal nerve fiber layer thickness (r=-0.35, p<0.001), and average ganglion cell-inner plexiform layer thickness (r=-0.35, p<0.05). However, after correcting for magnification effect, the results were considerably different, revealing only a positive correlation between axial length and temporal retinal nerve fiber layer thickness (r=0.42, p<0.001). Additionally, we demonstrated a positive correlation between axial length and average ganglion cell-inner plexiform layer thickness (r=0.48, p<0.001). All other correlations were not found to be statistically significant. Conclusions: Before adjustment for ocular magnification, axial length was negatively correlated with circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness measured by Cirrus-OCT. We attributed this effect to ocular magnification associated with greater axial lengths, which was corrected with the Littman's formula. Further studies are required to investigate the impact of ocular magnification correction on the diagnostic accuracy of Cirrus-OCT.


RESUMO Objetivo: Avaliar a influência do comprimento axial ocular na espessura da camada de fibras nervosas da retina peripapilar e na espessura da camada de células ganglionares-plexiforme interna em olhos saudáveis após correção para efeito de magnificação ocular. Métodos: Neste estudo transversal, avaliamos 120 olhos de 60 participantes voluntários (míopes, emétropes e hipermétropes). A espessura da camada de fibras nervosas da retina peripapilar e da camada de células ganglionares-plexiforme interna foram medidas usando a tomografia de coerência óptica espectral (OCT)-Cirrus HD-OCT e correlacionada com o comprimento axial ocular. O ajuste para a magnificação ocular foi realizado aplicando a fórmula de Littmann. Resultados: Antes do ajuste para magnificação ocular, a análise de modelos mistos ajustada por idade demonstrou uma correlação negativa significante entre o comprimento axial e a espessura média da camada de fibras nervosas da retina peripapilar (r=-0,43; p<0,001), espessura da camada de fibras nervosas da retina peripapilar inferior (r=-0,46; p <0,001), espessura da camada de fibras nervosas da retina peripapilar superior (r=-0,31; p<0,05), espessura da camada de fibras nervosas da retina peripapilar nasal (r=-0,35; p<0,001) e espessura média das células ganglionares-plexiforme interna (r=-0,35; p<0,05). No entanto, após a correção do efeito de magnificação, os resultados foram consideravelmente diferentes, revelando apenas uma correlação positiva entre o comprimento axial e a espessura temporal da camada de fibras nervosas da retina(r=0,42; p<0,001). Além disso, demonstramos uma correlação positiva entre o comprimento axial e a espessura média das células ganglionares-plexiforme interna (r=0,48; p<0,001). Todas as outras correlações não foram consideradas estatisticamente significativas. Conclusão: Antes do ajuste para o efeito de magnificação ocular, o comprimento axial estava negativamente correlacionado com a espessura da camada de fibras nervosas da retina peripapilar e das células ganglionares-plexiforme interna medido pelo Cirrus-OCT. Atribuimos esse efeito à magnificação ocular associada a comprimentos axiais maiores, o que foi corrigido com a fórmula de Littman. Mais estudos são necessários para investigaro impactoda correçãoda magnificação ocular na acurácia diagnóstica do Cirrus-OCT.


Subject(s)
Humans , Tomography, Optical Coherence , Retinal Ganglion Cells , Glaucoma , Cross-Sectional Studies , Nerve Fibers
8.
Arq. bras. oftalmol ; 83(1): 43-47, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088951

ABSTRACT

ABSTRACT Purpose: The aim of this study was to evaluate the effect of anterior chamber depth and axial length on clinical performance of the Spot Vision Screener in detecting amblyopia risk factors in children aged 3-10 years. Methods: A total of 300 eyes from 150 patients aged 3-10 years were prospectively tested with Spot Vision Screener (firmware version 3.0.02.32, software version 3.0.04.06) and a standard autorefractometer (Nidek ARK-1). The anterior chamber depth and axial length were measured with an optical biometer (Nidek AL-Scan). The sensitivity and specificity values for detecting significant refractive errors using the referral criteria of the American Association for Pediatric Ophthalmology and Strabismus were determined. Pearson's correlation analysis was employed to evaluate the relationship between the Spot Vision results and the anterior chamber depth and axial length. Results: Compared with the standard autorefractometer results, the Spot Vision Screener's sensitivity and specificity was 59% and 94%, respectively. The differences between the cycloplegic autorefractometer and the Spot Vision Screener spherical equivalents were negatively correlated with anterior chamber depth (r=-0.48; p<0.001) and axial length (r=-0.45; p<0.001). Conclusion: The Spot Vision Screener has moderate sensitivity and high specificity, using the criteria of the American Association for Pediatric Ophthalmology and Strabismus. The anterior chamber depth and axial length affect the Spot Vision results.


RESUMO Objetivo: O objetivo deste estudo foi avaliar o efeito da profundidade da câmara anterior e do comprimento axial sobre o desempenho clínico do Spot Vision Screener, na deteção de fatores de risco para a ambliopia em crianças de 3 a 10 anos de idade. Métodos: Um total de 300 olhos de 150 pacientes de 3-10 anos de idade foram prospectivamente testados com o Spot Vision Screener (firmware: 3.0.02.32, software: 3.0.04.06) e com autorefratómetro padrão (Nidek ARK-1). Todas as medições de profundidade e comprimento axial da câmara anterior dos pacientes foram realizadas através de Nidek AL Scan. A sensibilidade e especificidade para a deteção de erros refrativos significativos foram determinadas de acordo com os critérios de referência da Associação Americana de Oftalmologia e Estrabismo Pediátricos. A análise da Correlação de Pearson foi utilizada para avaliar a correlação entre os resultados do Spot Vision e a profundidade ou comprimento axial da câmara anterior dos pacientes. Resultados: Em comparação com os resultados do autorefratómetro padrão, a sensibilidade do Spot foi de 59% e a especificidade de 94%. As diferenças entre os equivalentes esféricos do autorefratómetro cicloplégico e o Spot Vision Screener foram correlacionados negativamente com a profundidade (r=-0,48; p<0,001) e o comprimento axial (r=-0,45; p<0,001) da câmara anterior dos casos. Conclusão: O Spot Vision Screener possui uma sensibilidade moderada e uma especificidade elevada utilizando os critérios da Associação Americana de Oftalmologia Pediátrica e Estrabismo; a profundidade da câmara anterior e o comprimento axial dos pacientes afetam os resultados do Spot Vision.


Subject(s)
Humans , Child, Preschool , Child , Vision Screening/instrumentation , Amblyopia/diagnosis , Refractive Errors/diagnosis , Amblyopia/etiology , Strabismus , Prospective Studies , Risk Factors , Sensitivity and Specificity , Retinoscopy , Axial Length, Eye , Anterior Chamber
9.
Arq. bras. oftalmol ; 82(3): 195-199, May-June 2019. tab
Article in English | LILACS | ID: biblio-1001305

ABSTRACT

ABSTRACT Purpose: To investigate changes in axial length after intravitreal dexamethasone implantation in patients with macular edema. Methods: We performed a prospective comparative study of 46 patients with unilateral macular edema, due to diabetic retinopathy, retinal vein occlusion, and non-infectious uveitis, who underwent dexamethasone implantation. The fellow eyes of the patients were considered the control group. The central macular thickness was measured by spectral-domain optical coherence tomography, and axial length was measured by IOLMaster 700 optical coherence biometry. We compared axial length and central macular thickness values within the groups. Results: In the study group, the baseline central macular thickness was 460.19 ± 128.64 mm, significantly decreasing to 324.00 ± 79.84 mm after dexamethasone implantation (p=0.000). No significant change in central macular thickness measurements was seen in the control group (p=0.244). In the study group, the baseline axial length was 23.16 ± 0.68 mm, significantly increasing to 23.22 ± 0.65 mm after dexamethasone implantation (p=0.039). However, the control group exhibited no significant change in axial length (p=0.123). Conclusions: In addition to significantly reducing central macular thickness measurements, intravitreal dexamethasone implantation also significantly changes optical biometry-based axial length measurements.


RESUMO Objetivo: Investigar alterações no comprimento axial após implante de dexametasona intravítrea em pacientes com edema macular. Métodos: Foi realizado um estudo prospectivo e comparativo de 46 pacientes com edema macular unilateral, devido à retinopatia diabética, oclusão da veia retiniana e uveíte não infecciosa, que foram submetidos ao implante de dexametasona. Os olhos contralateral de cada paciente foram considerados o grupo controle. A espessura macular central foi medida por tomografia de coerência óptica de domínio espectral, e o comprimento axial foi medido por meio de biometria de coerência óptica de domínio espectral e o comprimento axial foi medido pela biometria de coerência óptica com IOLMaster 700. Comparamos o comprimento axial e os valores da espessura macular central dentro dos grupos. Resultados: No grupo de estudo, a espessura macular basal foi de 460,19 ± 128,64 mm, diminuindo significativamente para 324,00 ± 79,84 mm após o implante de dexametasona (p=0,000). Nenhuma mudança significativa nas medidas da espessura macular central foi observada no grupo controle (p=0,244). No grupo de estudo, o comprimento axial basal foi de 23,16 ± 0,68 mm, aumentando significativamente para 23,22 ± 0,65 mm após o implante de dexametasona (p=0,039). No entanto, o grupo controle não apresentou alteração significativa no comprimento axial (p=0,123). Conclusões: Além de reduzir significativamente as medidas da espessura macular central, o implante de dexametasona intravítrea também altera significativamente as medidas de comprimento axial baseadas na biometria óptica.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Dexamethasone/administration & dosage , Macular Edema/drug therapy , Axial Length, Eye/drug effects , Intravitreal Injections/methods , Glucocorticoids/administration & dosage , Macula Lutea/drug effects , Visual Acuity , Macular Edema/pathology , Prospective Studies , Biometry/methods , Treatment Outcome , Statistics, Nonparametric , Tomography, Optical Coherence/methods , Diabetic Retinopathy/drug therapy , Axial Length, Eye/pathology , Macula Lutea/pathology
10.
Rev. bras. oftalmol ; 77(5): 268-271, set.-out. 2018. graf
Article in Portuguese | LILACS | ID: biblio-977865

ABSTRACT

Resumo Objetivos: Medir o ângulo lâmbda (AL) em indivíduos no pré-operatório de facectomias, correlacionando a sua presença com o comprimento axial e o esférico dos olhos. Sugerir condutas para o implante de LIO multifocal de acordo com a presença do ângulo lâmbda. Métodos: Estudo transversal em 128 olhos de 74 indivíduos candidatos à cirurgia de catarata para registrar a equivalente presença do ângulo lâmbda. Resultados: Avaliando o ângulo lâmbda observou-se uma correlação positiva (r= 0,559 / p= 0,000) para o tamanho desse ângulo comparando-se os dois olhos. Não houve correlação entre o tamanho do ângulo lâmbda e o equivalente esférico no olho direito (r= -0,027 / p= 0,840), mas foi verificada correlação positiva para o olho esquerdo (r= 0,313 / p= 0,013). A presença da hipermetropia correlacionou com os comprimentos axiais pequenos, assim como a miopia com os grandes. Observou-se correlação negativa entre o tamanho do ângulo lâmbda e o comprimento axial para os dois olhos, sendo de r= -0,249 para o olho direito (p= 0,042) e r= -0,281 para o olho esquerdo (p= 0,018) Conclusões: Houve correlação entre a presença de ângulo lâmbda maior e comprimentos axiais menores para os dois olhos. Para o equivalente esférico hipermétrope houve correlação com a presença de um ângulo lâmbda maior apenas para o olho esquerdo. Esse trabalho sugere parcimônia nos implantes de LIO multifocal na presença de ângulo lâmbda significativo, baseado na teoria que a presença desse ângulo é reguladora do equilíbrio entre as aberrações da superfície corneana versus cristalineanas.


Abstract Objectives: To measure the labral angle (LA) in individuals in the preoperative period of facectomies, correlating their presence with axial length and spherical equivalent of the eyes. Suggest conduits for the implantation of multifocal IOL according to the presence of the lambda angle. Methods: A cross-sectional study of 128 eyes of 74 individuals who were candidates for cataract surgery to record the presence of the lambda angle. Results: A positive correlation (r = 0.559 / p = 0.000) was observed for the angle of this angle by comparing the two eyes. There was no correlation between the size of the lambda angle and the spherical equivalent in the right eye (r = -0.027 / p = 0.840), but a positive correlation was observed for the left eye (r = 0.313 / p = 0.013). The presence of hyperopia correlated with small axial lengths, as did myopia with large ones. There was a negative correlation between the angle of the tongue and the axial length of the two eyes, with r = -0.249 for the right eye (p = 0.042) and = 0.281 for the left eye (p = 0.018). Conclusions: There was a correlation between the presence of a larger lambda angle and smaller axial lengths for both eyes. For the spherical hypermétrope equivalent, there was a correlation with the presence of a larger blunt angle only for the left eye. This work suggests parsimony in multifocal IOL implants in the presence of a significant lamella angle, based on the theory that the presence of this angle regulates the balance between corneal versus crystaline surface aberrations.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Pupil/physiology , Corneal Topography/methods , Lens Implantation, Intraocular , Axial Length, Eye , Multifocal Intraocular Lenses , Lighting , Cataract Extraction/statistics & numerical data , Cross-Sectional Studies , Biometry/instrumentation , Biometry/methods , Preoperative Period , Fixation, Ocular , Ocular Physiological Phenomena
11.
Arq. bras. oftalmol ; 79(4): 214-217, July-Aug. 2016. tab
Article in English | LILACS | ID: lil-794586

ABSTRACT

ABSTRACT Purpose: To evaluate variations in choroidal thickness (CT) during the water drinking test (WDT) in emmetropic eyes (EE) and highly myopic eyes (ME) using spectral-domain optical coherence tomography (SD-OCT). Methods: Clinical trial performed at a tertiary care hospital comprising 30 randomly selected eyes. The WDT and SD-OCT macular scans were performed 10 and 45 min after water ingestion in 15 myopic and 15 EE of 15 healthy patients in each group. Primary study outcomes were average macular CT measured by SD-OCT and intraocular pressure (IOP) during the WDT. Results: The mean spherical equivalent refraction was 0.15 ± 0.24 D in emmetropic and -7.1 ± 1.75 D in ME (p<0.001). No statistical differences between EE and ME were observed during the WDT response. EE had higher CT compared with ME at the fovea (361.4 ± 55.4 vs 257.9 ± 95.3; p<0.001), 3 mm nasal to the fovea (158.0 ± 71.8 vs 122.5 ± 54.5; p =0.047), and 3 mm temporally to the fovea (310.6 ± 52.4 vs 247.6 ± 90.1; p=0.05). Regarding CT variation, significant differences in foveal CT at 10 min after water ingestion were observed in both EE and ME, with no statistically significant difference observed between groups. A moderate correlation between IOP peak during the WDT and CT was demonstrated in ME (r=0.52; p=0.04). Conclusions: No statistically significant differences in CT variation during the WDT were observed between EE and ME, indicating similar behavior of the choroidal bed during the WDT in both groups. Further, CT was thinner in highly ME, with CT variation unable to explain elevations in IOP observed during the WDT.


RESUMO Objetivo: Avaliar a espessura de coroide (EC) e sua variação durante o teste de sobrecarga hídrica (TSH) em olhos emétropes (EE) e míopes (ME) utilizando a tomografia de coerência óptica Spectral-Domain (SD-OCT). Métodos: Ensaio clinico realizado em um hospital terciário. 30 olhos selecionados randomizadamente, 15 míopes e 15 emétropes de 15 pacientes em cada grupo foram submetidos ao TSH e scans maculares com SD-OCT realizados 10 e 45 minutos após a ingestão de água. Os principais resultados avaliados foram média da EC na região macular pelo SD-OCT e pressão intraocular (PIO) durante o TSH. Resultados: O equivalente esférico médio foi de 0.15 ± 0.24 dioptrias em emétropes e -7,1 ± 1,75 dioptrias nos olhos míopes (p<0,001). Não foram encontradas diferenças estatísticas durante a resposta ao TSH entre EE e ME. EE apresentaram maior EC em comparação com ME, tanto na região foveal (361,4 ± 55,4 vs 257,9 ± 95,3; p<0,001), 3 milímetros nasal à fóvea (158,0 ± 71,8 vs 122,5 ± 54,5; p=0,047) e 3 mm temporal à fóvea (310,6± 52.4 vs 247,6 ± 90,1; p=0,05). Em relação à variação da EC, diferenças estatisticamente significativas foram demonstrados na região foveal, 10 minutos após a ingestão de água em ambos EE e ME, sem diferenças entre os grupos. Moderada correlação entre pico de PIO durante o TSH e EC foi demonstrada em ME ( r=0,52; p=0,04). Conclusão: A diferença na variação da EC provocada pelo TSH não foi estatisticamente diferente entre olhos emétropes e míopes, o que sugere um comportamento semelhante da coroide nestes dois grupos quando submetidos ao TSH. Além disso, a EC é mais fina nos olhos alto míopes, e a variação na EC não explica o aumento da PIO durante o TSH.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Drinking Water/administration & dosage , Choroid/pathology , Tomography, Optical Coherence/methods , Diagnostic Techniques, Ophthalmological , Myopia/pathology , Reference Values , Time Factors , Glaucoma/physiopathology , Glaucoma/pathology , Reproducibility of Results , Choroid/physiopathology , Axial Length, Eye , Fovea Centralis/physiopathology , Fovea Centralis/pathology , Intraocular Pressure/physiology , Myopia/physiopathology
12.
Arq. bras. oftalmol ; 79(3): 143-146, tab, graf
Article in English | LILACS | ID: lil-787335

ABSTRACT

ABSTRACT Purpose: To investigate subfoveal choroidal thickness (SFCT) in patients with pre-eclampsia using enhanced depth imaging optical coherence tomography (EDI-OCT). Methods: A sample of 73 pregnant women was studied over 28 weeks of gestation. The sample was divided into two groups: one comprising pre-eclamptic pregnant women (n=32), and the other comprising healthy pregnant women (n=41). The SFCT was determined for all patients using EDI-OCT during pregnancy and at the third month of the postpartum period. Results: The SFCTs in pre-eclamptic pregnant women were 351.97 ± 22.44 and 332.28 ± 20.32 µm during the pregnancy and postpartum periods (p<0.001), respectively, whereas these values in healthy pregnant women were 389.73 ± 49.64 and 329.78 ± 22.36 µm (p<0.001), respectively. During pregnancy SFCT in pre-eclamptic pregnant women was significantly thinner than that in healthy pregnant women (p<0.001). However, there was no statistically significant difference during the postpartum period (p=0.623). Conclusions: The results suggest that SFCT is significantly decreased in pre-eclamptic pregnant women than in healthy pregnant women, despite no statistically significant difference in SFCT existing between the groups during the postpartum period.


RESUMO Objetivo: Investigar espessura subfoveal coroidal (SFCT) em pacientes com pré-eclâmpsia usando imagens de tomografia de coerência óptica de profundidade otimizada (EDI-OCT). Método: Uma amostra de 73 mulheres grávidas foi estudado ao longo de 28 semanas de gestação. A amostra foi dividida em dois grupos: um com mulheres grávidas com pré-eclâmpsia (n=32), o outro com as mulheres grávidas saudáveis (n=41). SFCT foi determinada em todos os pacientes utilizando EDI-OCT durante a gravidez e no terceiro mês do período pós-parto. Resultados: Os SFCTs em gestantes com pré-eclâmpsia foram 351,97 ± 22,44 µm e 332,28 ± 20,32 µm durante o período de gravidez e pós-parto (p<0,001), respectivamente. Estes valores em mulheres grávidas saudáveis foram 389,73 ± 49,64 µm e 329,78 ± 22,36 µm (p<0,001), respectivamente. Durante a gravidez o SFCT foi significantemente mais fino em mulheres com pré-eclâmpsia quando comparado com as mulheres saudáveis (p<0,001). No entanto, não houve diferença estatisticamente significante no período pós-parto (p=0,623). Conclusões: Os resultados sugerem que SFCT é significativamente mais fino em gestantes com pré-eclâmpsia do que nas mulheres grávidas saudáveis, apesar de não haver diferença estatisticamente significativa na SFCT entre os grupos durante o período pós-parto.


Subject(s)
Humans , Female , Adolescent , Adult , Young Adult , Pre-Eclampsia/pathology , Choroid/pathology , Postpartum Period/physiology , Fovea Centralis/physiopathology , Fovea Centralis/pathology , Organ Size , Pre-Eclampsia/physiopathology , Reference Values , Time Factors , Pregnancy/physiology , Case-Control Studies , Cross-Sectional Studies , Choroid/physiopathology , Gestational Age , Statistics, Nonparametric , Tomography, Optical Coherence/methods , Axial Length, Eye , Intraocular Pressure
13.
Arq. bras. oftalmol ; 79(1): 19-23, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-771898

ABSTRACT

ABSTRACT Purpose: To evaluate the ocular axial length (AL) and keratometry (K) in Brazilian children with congenital/developmental cataract, assess the differences and evolution of AL and K according to age, and establish functional models of AL and K as function of age. Methods: Children with congenital/developmental cataract aged 1.5 months old to 8 years old and no other ocular diseases were included. All eyes with unilateral cataract, the left eyes from children with bilateral cataracts, and healthy eyes from children with unilateral cataract were analyzed. After the administration of anesthesia, K was measured with a portable automatic keratometer, and AL was measured with a contact biometer. Cataract surgery was performed immediately after the measurements were taken. The data were statistically analyzed, and a linear regression with an age logarithm was used to model the relationship. Results: Forty-four eyes with cataract were included in this analysis, comprising 15 eyes with unilateral cataract and 29 left eyes from children with bilateral cataracts. The mean age was 27.3 months with a mean AL of 20.63 ± 2.11 mm and a mean K of 44.94 ± 2.44 D. The K value was significantly steeper and the AL value was significantly shorter in younger children (P< 0.001). No significant differences were found neither between eyes with unilateral and bilateral cataracts nor between eyes with unilateral cataract and their corresponding healthy eyes (P >0.05). Conclusion: The values of K and AL significantly change with age, especially during the first 6 months of life. A linear functional relationship between K and AL with the logarithm of age and between K and AL was established.


RESUMO Objetivo: Avaliar o comprimento axial (AL) e a ceratometria (K) de olhos de crianças brasileiras com catarata congênita/desenvolvimento, analisar diferenças e evoluções de acordo com a idade e estabelecer modelos funcionais de comprimento axial e ceratometria em função da idade e entre eles. Métodos: Crianças com catarata congênita/desenvolvimento com idade de 1,5 meses a 8 anos de idade e sem outras doenças oculares foram incluídas. Todos os olhos com catarata unilateral, o olho esquerdo de crianças com catarata bilateral e o olho sadio de crianças com catarata unilateral foram analisados. Após a administração de anestesia, a ceratometria foi obtida com um ceratômetro automático portátil e o comprimento axial medido com um biômetro de contato. Em seguida, a cirurgia de catarata foi realizada. Os dados foram analisados estatisticamente, a regressão linear com o logaritmo da idade foi utilizado para modelar os relacionamentos. Resultados: Todos os olhos com catarata unilateral (n=15) e um olho selecionados aleatoriamente a partir dos casos bilaterais (n=29) foram incluídos na análise (total= 44 olhos). A idade média foi de 27,3 meses, as médias do comprimento axial e da ceratometria foram respectivamente 20,63 ± 2,11 mm e 44,94 ± 2,44 dioptrias. A ceratometria foi significativamente mais curvo e comprimento axial significantemente mais curto em crianças mais jovens (P<0,001). Não foram encontradas diferenças significativas na comparação entre os olhos com cataratas unilaterais e bilaterais e comparando os olhos com catarata unilateral a correspondentes olhos saudáveis (P>0,05). Conclusão: Os valores de ceratometria e comprimento axial mudam significativamente com a idade, principalmente nos primeiros seis meses de vida. Foi estabelecida uma relação funcional linear entre comprimento axial e ceratometria com o logaritmo da idade e entre ceratometria e comprimento axial.


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Axial Length, Eye/pathology , Cataract/congenital , Cataract/pathology , Cornea/pathology , Age Factors , Brazil , Biometry/methods , Cataract/physiopathology , Linear Models , Reference Values , Retrospective Studies
14.
Arq. bras. oftalmol ; 78(3): 146-149, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-753019

ABSTRACT

ABSTRACT Purpose: To analyze ocular biometry parameters and evaluate their relationship with gestational age, birth weight, and postmenstrual age in prematurely born infants. Methods: The right eyes of 361 premature infants born before the 36th gestational week were evaluated. Birth weight, gestational week, and gender were recorded. An A-scan Biometer was used for obtaining axial measurements, including anterior chamber depth, lens thickness, vitreous length, and total axial length. Results: Gestational age and birth weight values ranged from 23 to 36 weeks and from 560 to 2,670 g, respectively. The mean gestational age and birth weight were 30.8 ± 2.8 weeks and 1,497.9 ± 483.6 g, respectively. During the first examination (4-5 weeks of postnatal age), birth weight and gestational age of the infants correlated significantly and positively with lens thickness, vitreous length, and axial length (r>0.5, p<0.001), but not with anterior chamber depth (r<0.5). Increased vitreous and axial lengths correlated significantly with increasing postmenstrual age of the infants (r=0.669, p<0.001; r=0.845, p<0.001, respectively). Conclusions: Lens thickness, vitreous length, and axial length, but not anterior chamber depth, were significantly correlated with birth weight and gestational age. All four parameters increased with increasing postmenstrual age, with higher correlations for vitreous and axial lengths than for anterior chamber depth and lens thickness. It was concluded that axial elongation resulted primarily from increasing posterior chamber length. .


RESUMO Objetivo: Medir os comprimentos axiais dos componentes oculares e avaliar a relação com a idade gestacional, peso ao nascer e idade pós-menstrual em crianças nascidas prematuramente. Método: O olho direito de 361 crianças prematuras, que nasceram com menos de 36 semanas de gestação, foram avaliados. O peso ao nascer, semanas de gestação e gênero foram registrados. Um biômetro A-scan foi utilizado para a obtenção das medidas axiais da profundidade da câmara anterior, espessura do cristalino, comprimento vítreo e comprimento axial total. Resultados: A idade gestacional e os valores de peso ao nascimento variaram de 23 a 36 semanas e de 560 a 2.670 g, respectivamente. A idade gestacional e o peso ao nascer foram 30,8 ± 2,8 semanas e 1.497,9 ± 483,6 g. Ao primeiro exame (4 a 5 semanas de idade pós-natal), o peso ao nascimento e a idade gestacional dos recém-nascidos apresentaram correlação positiva, estatisticamente significativa, com a espessura do cristalino, comprimento vítreo e comprimento axial total (r>0,5 p<0,001), mas não com a profundidade da câmara anterior (r<0,5). O alongamento de comprimento vítreo e do comprimento axial total se correlacionaram significativamente com o aumento da idade pós-menstrual dos lactentes (r=0,669; p<0,001 e r=0,845; p<0,001, respectivamente). Conclusões: A espessura do cristalino, o comprimento vítreo e o comprimento axial total, mas não profundidade da câmara anterior, foram significativamente correlacionados com o peso ao nascimento e com a idade gestacional. Todos os quatro componentes aumentaram com a idade pós-menstrual, apresentando correlações mais elevadas do comprimento vítreo e comprimento axial total do que da profundidade da câmara anterior e espessura do cristalino. Concluiu-se que o alongamento axial resultou principalmente do aumento do comprimento da câmara posterior. .


Subject(s)
Female , Humans , Infant , Infant, Newborn , Male , Pregnancy , Birth Weight/physiology , Gestational Age , Infant, Premature/growth & development , Retinopathy of Prematurity/physiopathology , Age Factors , Anterior Chamber/anatomy & histology , Axial Length, Eye/physiology , Biometry , Cohort Studies , Follow-Up Studies , Infant, Low Birth Weight/growth & development , Lens, Crystalline/anatomy & histology , Sex Factors , Vitreous Body/anatomy & histology
15.
Arq. bras. oftalmol ; 78(1): 23-26, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741157

ABSTRACT

Purpose: To investigate the association between central choroidal thickness (CT), axial length (AL), age, gender, and refractive error in a healthy pediatric population using optical coherence tomography (OCT). Methods: This institutional study involved 137 healthy children (57 boys, 80 girls) aged between 4 and 18 years. Each child underwent a dilated eye examination, cycloplegic refraction, and AL measurement using a Nidek AL-Scan optical biometer. The central foveal thickness (CFT) and CT were measured using Cirrus high definition (HD)-OCT. The right eye of each subject was selected for analysis. Results: The mean age of the children was 10.0 ± 4.7 years (range, 4-18 years). The mean spherical equivalent (SE) was -0.24 ± 1.24 diopters (D) (range, -2.00 D to +2.25 D). The mean AL was 23.1 ± 1.2 mm (range, 20-27 mm). The mean central CT was 388.2 ± 50.0 μm and was not correlated with age, gender, AL, or refractive error. Conclusion: The data provide a pediatric normative database of CT using enhanced depth imaging OCT. This information may be useful in the diagnosis and monitoring of retino-choroidal diseases in children. .


Objetivo: Investigar a associação entre a espessura central da coroide e o comprimento axial (AL), idade, sexo e erros de refração em uma população pediátrica saudável por meio da tomografia de coerência óptica (OCT). Métodos: Estudo institucional envolvendo 137 crianças saudáveis (57 meninos, 80 meninas), com idades entre 4 e 18 anos. Cada criança foi submetida a um exame de fundo de olho, refração sob cicloplegia e medida do comprimento axial usando o biométrico óptico Nidek AL-Scan (Nidek CO, LTD.). A espessura foveal central (CFT) e espessura da coroide (CT) foram medidas utilizando o Cirrus HD-OCT (Carl Zeiss Meditec). O olho direito de cada sujeito foi selecionado para análise. Resultados: A idade média das crianças foi de 10,0 ± 4,7 anos (variação, 4 a 18 anos). O equivalente esférico médio (SE) foi -0,24 ± 1,24 dioptrias (D) (variação de -2,00 D a +2,25 D). A média do comprimento axial foi de 23,1 ± 1,2 mm (variação, 20 a 27 mm). A espessura da coroide central média foi de 388,2 ± 50,0 mm e não se correlacionou com a idade, sexo, comprimento axial ou erro refrativo. Conclusão: Os resultados proporcionam uma base de dados pediátrica normativa da espessura da coroide usando tomografia de coerência óptica com profundidade de imagem aprimorada. Esta informação pode ser útil no diagnóstico e acompanhamento de doenças de retina e coroide em crianças. .


Subject(s)
Adolescent , Child , Child, Preschool , Female , Humans , Male , Axial Length, Eye/physiology , Choroid/anatomy & histology , Tomography, Optical Coherence/methods , Age Factors , Fundus Oculi , Reference Values , Refractive Errors , Sex Factors , Visual Acuity/physiology
16.
Arq. bras. oftalmol ; 77(3): 152-154, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-723839

ABSTRACT

Purpose: To investigate the distribution of axial length, anterior chamber depth, lens thickness, vitreous chamber depth, and central corneal thickness in children at different age groups. Methods: We studied 364 eyes in 182 children with ages between 1 and 12 years. Axial length, anterior chamber depth, lens thickness, and vitreous chamber depth were measured by ultrasound biometry. Central corneal thickness was measured by ultrasound pachymetry in all children. Results: The mean age was 6.54 ± 3.42 years. The axial length was 20.95 mm in 1-2 years old and 22.95 mm in 11-12 years old. The central corneal thickness was 556 µm in 1-2 years old and 555 µm in 11-12 years old. The mean anterior chamber depth and vitreous chamber depth increased with age (3.06 mm to 3.44 mm in anterior chamber depth, 13.75 mm to 15.99 mm in vitreous chamber depth), and the lens thickness decreased as age increased (3.67-3.51 mm). Conclusion: The axial length increased with age and reached adult levels by the age of 9-10 years. The lens thickness gradually decreased until 12 years. The central corneal thickness measurements did not yield a linear algorithm. .


Objetivo: Investigar a distribuição do comprimento axial, profundidade da câmara anterior, espessura do cristalino, profundidade da câmara vítrea e espessura corneal central em crianças em diferentes faixas etárias. Métodos: Foram estudados 364 olhos de 182 crianças entre 1 e 12 anos de idade. O comprimento axial, a profundidade da câmara anterior , a espessura do cristalino e a profundidade da câmara vítrea foram medidos por biometria ultrassônica. A espessura corneal central foi medida por paquimetria ultrassônica em todas as crianças. Resultados: A idade média foi de 6,54 ± 3,42 anos. O comprimento axial foi 20,95 mm no grupo de 1-2 anos de idade e 22,95 mm no grupo de 11-12 anos de idade. A espessura corneal central foi 556 µm no grupo de 1-2 anos de idade e 555 µm no grupo de 11-12 anos de idade. A profundidade da câmara anterior média e profundidade da câmara vítrea aumentou com a idade (3,06 mm a 3,44 mm de profundidade da câmara anterior, 13,75 mm a 15,99 mm de profundidade da câmara vítrea) e da espessura do cristalino diminuiu com o aumento da idade (3,67 mm a 3,51 mm). Conclusões: Em nosso estudo, os valores do comprimento axial aumentou com a idade e atingiu os níveis adultos aos 9-10 anos de idade. A espessura do cristalino diminuiu gradualmente até os 12 anos de idade. As medições de espessura corneal central não seguiu um algoritmo linear. .


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Biometry/methods , Eye/anatomy & histology , Age Factors , Analysis of Variance , Cornea/anatomy & histology , Cornea , Eye , Organ Size , Reference Values , Retrospective Studies , Sex Factors
17.
Arq. bras. oftalmol ; 76(5): 265-269, set.-out. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-690601

ABSTRACT

OBJETIVO: Determinar se o crescimento do globo ocular mensurado através da biometria óptica e ultrassônica em uma população pediátrica de altos míopes é significante, assim como variação significante da espessura do cristalino, profundidade da câmara anterior, curvatura corneana e achados fundoscópicos durante o acompanhamento. MÉTODOS: Uma população pediátrica (idade média: 8,7anos), 11 olhos de crianças portadoras de alta miopia (refração média inicial: -11,28D) foi submetida a avaliação seriada num período de nove meses incluindo-se biometria óptica (IOLMaster, Zeiss) e ultrassônica (Ultrascan, Alcon; técnica de contato), refratometria estática, oftalmoscopia indireta e retinografia. RESULTADOS: No período de nove meses, o crescimento do olho foi estatisticamente significante em 64% (7 olhos) e não ocorreu em 36% (3 olhos), com modificação do comprimento axial médio (pré=26,76 mm; final=26,98 mm). Neste período, o equivalente esférico refracional aumentou em 45% (5 olhos), não apresentou variação em 27% (3 olhos), com modificação da refração média (pré=-11,28 D; final=-11,69 D). Não houve variação estatisticamente significante da espessura do cristalino, profundidade da câmara anterior, curvatura corneana e do aspecto fundoscópico. CONCLUSÃO: No grupo de crianças com alta miopia acompanhadas num período de nove meses, demonstrou-se o crescimento do globo ocular com variação do comprimento axial tanto pela técnica de biometria óptica quanto ultrassônica, e com aumento da refratometria média. Outros parâmetros estudados como espessura do cristalino, profundidade da câmara anterior e curvatura da córnea não demonstraram variação no período de tempo do estudo.


PURPOSE: To determine if the growth of the axial length measured by optical and ultrasound biometry in a pediatric population of high myopes is significant, as well as significant variation of lens thickness, anterior chamber depth, corneal curvature and ophthalmoscopic findings during follow-up. METHODS: A pediatric population (mean age: 8.7 years old) of 11 high myopic eyes (mean initial refractive error: -11.28 D) was submitted to serial evaluation over a 9-months period including optical (IOLMaster, Zeiss) and ultrasound biometry (Ultrascan, Alcon, contact technique), cycloplegic refraction, indirect ophthalmoscopy and fundus photography. RESULTS: During a 9-months period, eye growth was significant in 64% (7 eyes) and did not occur in 36% (3 eyes), with change in the mean axial length (pre=26.76 mm; final=26.98 mm). During this period, refractive spherical equivalent increased in 45% (5 eyes), did not show variation in 27% (3 eyes), with a change in mean refraction (pre=-11.28 D; final=-11.69 D). There was no statistically significant variation of lens thickness, anterior chamber depth, corneal curvature and ophthalmoscopic findings. CONCLUSION: Ocular globe growth (axial length) measured by optic and ultrasound biometry was significant in the high myopic pediatric population examined. The findings suggest that axial length variation preceded variation of other structures in the sample examined. In a group of children with high myopia followed during a 9-months period, ocular growth was demonstrated with variation of axial length either with optical or ultrasound biometry techniques, and change in mean refraction. Other parameters studied as lens thickness, anterior chamber depth and corneal curvature did not demonstrate variation during the time of the study.


Subject(s)
Child , Child, Preschool , Female , Humans , Male , Axial Length, Eye , Biometry/methods , Eye/growth & development , Myopia/physiopathology , Anterior Chamber , Cohort Studies , Corneal Topography , Disease Progression , Electroretinography , Eye/pathology , Fundus Oculi , Lens, Crystalline , Ophthalmoscopy , Refractometry , Visual Acuity
18.
Rev. bras. oftalmol ; 72(2): 103-107, mar.-abr. 2013. graf, tab
Article in English | LILACS | ID: lil-678375

ABSTRACT

OBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer. METHODS: The measurements for IOL calculation were obtained through optical biometry by partial coherence interferometry (IOL Master®- Zeiss, 5.4 and 5.5 version) that provides us with the axial length, the central keratometry of 2.5mm, white-to-white diameter and anterior chamber anatomical depth. The formula chosen was Haigis. The surgical technique applied was with the scleral incision at 1.5 mm from the limbus, with scleral-corneal tunnel of 2.2 mm wide, phacoemulsification using INFINITI Ozil®- Alcon and implantation of hydrophobic acrylic aspheric intraocular lens - SN60WF®- Alcon. RESULTS: We studied 20 eyes submitted to keratotomy in the past and currently with cataract with indication for cataract surgerywith intraocular lens implantation using phacoemulsification. Postoperative spherical equivalent was plano in 40% of the eyes and lower than -1.00 in 85% of the eyes. CONCLUSION: The optical biometry by partial coherence interferometry associated with Haigis formula is a valid alternative in IOL calculation for eyes submitted to keratotomy. The refractive results are highly predictable and reproducible.


OBJETIVO: Analisar os resultados refracionais no pós-operatório de cirurgia de catarata em olhos previamente submetidos à ceratotomia, utilizando a fórmula Haigis e os dados fornecidos pelo biômetro óptico IOL Master®. MÉTODOS: As medidas para o cálculo da LIO foram obtidas por meio da biometria óptica por interferometria de coerência parcial (IOL Master® - Zeiss, versão 5.4 e 5.5) que nos fornece o comprimento axial, a ceratometria central de 2.5mm, o diâmetro branco-a-branco e a profundidade anatômica da câmara anterior. A fórmula escolhida foi a Haigis. A técnica cirúrgica aplicada foi com incisão escleral a 1.5mm do limbo, com túnel esclero-corneal de 2.2mm de largura, facoemulsificação com equipamento INFINITI Ozil® - Alcon e implante de lente intraocular acrílica hidrofóbica asférica - SN60WF® - Alcon. RESULTADOS: Foram estudados 20 olhos submetidos à ceratotomia no passado e atualmente portadores de catarata com indicação de facectomia com implante de lente intraocular por meio da facoemulsificação. O equivalente esférico pós-operatório foi plano em 40% dos olhos e menor que -1.00 em 85% dos olhos. CONCLUSÃO: A biometria óptica por interferometria de coerência parcial associada à fórmula Haigis se apresenta como uma alternativa válida no cálculo da LIO em olhos submetidos à ceratotomia. Os resultados refrativos são altamente previsíveis e reproduzíveis.


Subject(s)
Humans , Anterior Chamber , Axial Length, Eye , Biometry/methods , Cataract Extraction , Keratotomy, Radial , Lenses, Intraocular , Retrospective Studies , Treatment Outcome
19.
Arq. bras. oftalmol ; 75(1): 38-42, jan.-fev. 2012. ilus, tab
Article in English | LILACS | ID: lil-622544

ABSTRACT

PURPOSE: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. RESULTS: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). CONCLUSIONS: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.


OBJETIVO: Investigar a contribuição individual da profundidade da câmara anterior, da espessura do cristalino e da profundidade da câmara vítrea para o comprimento axial total em pacientes com ambliopia por esotropia. MÉTODOS: Foram incluídas 74 crianças com idade entre 5 e 8 anos, sendo 37 pacientes com ambliopia por esotropia e 37 voluntários sadios (grupo controle). Foi realizado exame oftalmológico completo, incluindo refração sob cicloplegia e ultrassonografia modo A. Foram registrados profundidade da câmara anterior, espessura do cristalino, profundidade da câmara vítrea e comprimento axial total. A contribuição individual de cada componente para o comprimento axial total foi relatada como valor porcentual e teste t de Student pareado foi utilizado para a comparação entre olho amblíope e olho contralateral e entre olho direito e esquerdo no grupo controle. RESULTADOS: Olhos amblíopes, quando comparados aos olhos contralaterais, apresentaram maior contribuição da espessura do cristalino (P=0,001), menor contribuição da profundidade da câmara vítrea (P=0,001) e contribuição semelhante da profundidade da câmara anterior (P=0,434) para o comprimento axial total. A comparação entre olho direito e olho esquerdo no grupo controle mostrou contribuições semelhantes da profundidade da câmara anterior (p=0,620), da espessura do cristalino (P=0,721) e da profundidade da câmara vítrea (P=0,483) para o comprimento axial total. CONCLUSÕES: Este estudo mostrou diferenças entre olhos amblíopes e não amblíopes quando o comprimento axial total é dividido nas contribuições individuais dos seus componentes.


Subject(s)
Child , Child, Preschool , Humans , Amblyopia , Anterior Chamber , Esotropia , Lens, Crystalline , Vitreous Body , Amblyopia/etiology , Biometry , Case-Control Studies , Corneal Topography , Esotropia/complications